1.
Proc Natl Acad Sci U S A ; 119(27): e2200109119, 2022 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-35763573

RESUMO

Understanding the factors that influence the airborne survival of viruses such as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in aerosols is important for identifying routes of transmission and the value of various mitigation strategies for preventing transmission. We present measurements of the stability of SARS-CoV-2 in aerosol droplets (∼5 to 10 µm equilibrated radius) over timescales spanning 5 s to 20 min using an instrument to probe survival in a small population of droplets (typically 5 to 10) containing ∼1 virus/droplet. Measurements of airborne infectivity change are coupled with a detailed physicochemical analysis of the airborne droplets containing the virus. A decrease in infectivity to ∼10% of the starting value was observable for SARS-CoV-2 over 20 min, with a large proportion of the loss occurring within the first 5 min after aerosolization. The initial rate of infectivity loss was found to correlate with physical transformation of the equilibrating droplet; salts within the droplets crystallize at relative humidities (RHs) below 50%, leading to a near-instant loss of infectivity in 50 to 60% of the virus. However, at 90% RH, the droplet remains homogenous and aqueous, and the viral stability is sustained for the first 2 min, beyond which it decays to only 10% remaining infectious after 10 min. The loss of infectivity at high RH is consistent with an elevation in the pH of the droplets, caused by volatilization of CO2 from bicarbonate buffer within the droplet. Four different variants of SARS-CoV-2 were compared and found to have a similar degree of airborne stability at both high and low RH.


Assuntos
Partículas e Gotas Aerossolizadas , COVID-19 , SARS-CoV-2 , Partículas e Gotas Aerossolizadas/química , Partículas e Gotas Aerossolizadas/isolamento & purificação , COVID-19/transmissão , Humanos , Umidade , Concentração de Íons de Hidrogênio , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/patogenicidade
2.
Eur J Pharm Biopharm ; 166: 10-18, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34082122

RESUMO

The purpose of these studies was to understand the effect on product performance of batch-to-batch variability in both the amikacin liposome inhalation suspension (ALIS) formulation and its delivery device, the Lamira® nebulizer system, designed and manufactured by PARI (PARI Pharma GmbH, Munich, Germany). Three batches of ALIS spanning a range of lipid concentrations (43, 48 and 54 mg/mL) were tested with nine PARI inhalation devices that varied within the production process of the vibrating membrane with respect to hole geometry. Three hole geometry clusters were built including a geometry close to the mean geometry (median) and two geometries deviating from the mean geometry with smaller (smaller) and larger (larger) holes. The output parameters included the nebulization rate, the aerosol droplet size distribution, the liposome vesicle size post-nebulization, and the fraction of amikacin that remained encapsulated post-nebulization. Across the 27 experimental combinations of three formulation batches and nine devices, the nebulization time varied between 12 and 15 min with the fastest nebulization rate occurring with the combination of low lipid concentration and larger hole geometry (0.68 g/min) and the slowest nebulization rate occurring with the combination of high lipid concentration and the smaller hole geometry (0.59 g/min). The mean liposome vesicle size post-nebulization ranged from 269 to 296 nm across all experimental combinations which was unchanged from the control samples (276-292 nm). While all three batches contained > 99% encapsulated amikacin prior to nebulization, the nebulization process resulted in a consistent generation of ~ 35% unencapsulated amikacin (range: 33.8% to 37.6%). There was no statistically significant difference in the generated aerosol particle size distributions. The mass median aerodynamic diameters (MMAD) ranged from 4.78 µm to 4.98 µm, the geometric standard deviations (GSD) ranged from 1.61 to 1.66, and the aerosol fine particle fraction (FPF < 5 µm) ranged from 50.3 to 53.5%. The emitted dose (ED) of amikacin ranged from 473 to 523 mg (80.2 to 89.3% of loaded dose (LD)) and the fine particle dose (FPD < 5 µm) ranged from 244 to 278 mg (41.4 to 47.1% of label claim (LC)). In conclusion, while variations in the lipid concentration of the ALIS formulation and the device hole geometry had a small but significant impact on nebulization time, the critical aerosol performance parameters were maintained and remained within acceptable limits.


Assuntos
Amicacina , Composição de Medicamentos/métodos , Sistemas de Liberação de Medicamentos , Nebulizadores e Vaporizadores , Administração por Inalação , Partículas e Gotas Aerossolizadas/química , Partículas e Gotas Aerossolizadas/farmacologia , Aerossóis/administração & dosagem , Aerossóis/farmacologia , Amicacina/administração & dosagem , Amicacina/farmacologia , Antibacterianos/administração & dosagem , Antibacterianos/farmacologia , Sistemas de Liberação de Medicamentos/instrumentação , Sistemas de Liberação de Medicamentos/métodos , Desenho de Equipamento , Lipídeos/química , Lipossomos